loading spinner

Air-to-Electric Converter

This air gauging module converts the differential pressure derived from a pneumatic measuring system into an analog electrical signal. Thus, distances can be measured to around 1 µm precision. Most air gauging systems employ several of these converters simultaneously.

If you are interested in this or a similar project, please contact us.

Contact us

Air-to-Electric Converter Features

  • Input power: 24 Vdc
  • Supplied with bi-colored LED for visual status/error indication
  • Performs a system self-test upon power-up
  • Checks for minimum system pressure
  • Single- or dual-scale pressure range
  • Output signal 1 to 10 V (0 V indicates error)
  • Output signal 4 to 20 mA (0 mA indicates error)
  • Output signals can withstand a short circuit indefinitely
  • Output signal is bounded when output is saturated beyond ±full scale (or not)
  • Factory electrical testing and calibration accommodated through an onboard socket
  • All calibrations stored in nonvolatile memory
  • All units are bubble tested for leaks

Air-to-Electric Converter Technical Specifications

Input Power
24 Vdc @ ~40 mA
System Pressure
30 PSIG sensor
Signal Pressure
15 PSID sensor
Size
3 x 2 in (76 x 51 mm) PCB

Contact Us AboutAir-to-Electric Converter

If you are interested in this, or a project similar to this, please contact us.

Contact us